Followers

Friday, October 23, 2026

Newtonian and plastic of Bingham Reynolds number calculator

Reynolds Number Calculator: Newtonian vs. Bingham Plastic Fluid

Author: Cesar Caballero Medrano  |  Date of creation: October 22, 2026

What this app does: it calculates and compares the Reynolds number of a Newtonian fluid and of a Bingham plastic fluid flowing in a circular pipe, and tells you whether each flow is laminar or turbulent. Inputs can be entered in SI or British units.

How to use this app
  1. Select the unit system (SI or British). If you change it, the values already typed are converted automatically.
  2. Enter the pipe inside diameter, the fluid density and the flow, either as average velocity or as volumetric flow rate.
  3. Enter the viscosity of the Newtonian fluid, and the plastic viscosity and yield stress of the Bingham plastic.
  4. Press Calculate. The app shows both Reynolds numbers side by side, the Hedström number, the flow regime of each fluid and a comparison.
Both fluids are assumed to flow in the same pipe, with the same density and the same flow, so that the effect of the rheology can be compared directly. Use Load example to see a sample case.

Equations used

Newtonian fluid

$$ Re_N = \frac{\rho \, v \, D}{\mu} $$

Bingham plastic fluid (Bingham Reynolds number, based on the plastic viscosity)

$$ Re_B = \frac{\rho \, v \, D}{\mu_p} \qquad\qquad He = \frac{\rho \, \tau_y \, D^2}{\mu_p^2} $$

Average velocity from volumetric flow rate

$$ v = \frac{4\,Q}{\pi D^2} $$

Critical Reynolds number for a Bingham plastic (Hanks). First solve for $\phi_c = \tau_y/\tau_w$ at the transition:

$$ \frac{He}{16800} = \frac{\phi_c}{(1-\phi_c)^3} \qquad\qquad Re_{B,c} = \frac{He}{8\,\phi_c}\left(1 - \frac{4}{3}\phi_c + \frac{\phi_c^{4}}{3}\right) $$

Where: $\rho$ = density, $v$ = average velocity, $D$ = inside diameter, $Q$ = volumetric flow rate, $\mu$ = Newtonian viscosity, $\mu_p$ = plastic viscosity, $\tau_y$ = yield stress, $\tau_w$ = wall shear stress. For the Newtonian fluid, the flow is laminar for $Re_N < 2100$ and turbulent for $Re_N > 4000$. For the Bingham plastic the flow is laminar when $Re_B < Re_{B,c}$.

Sketch of the two fluid models

Rheogram (shear stress vs. shear rate) Shear rate, dv/dr Shear stress, τ τy (yield stress) Newtonian Bingham plastic Laminar velocity profiles in a pipe Plug core (no shear) Newtonian: parabolic Bingham: flattened Pipe wall Pipe diameter D v = 0 The Newtonian fluid starts to flow at any stress. The Bingham plastic needs a stress above its yield stress τy, so a central plug moves as a solid body.

Input data

Results

Press Calculate to see the results.

Note: results are for educational purposes. The Hanks criterion is valid for Bingham plastics in circular pipes.

Thursday, October 22, 2026

Triple-effect evaporator heat balance solver - Backward feed - SI

Triple-Effect Evaporator Heat Balance Solver

Backward-Feed Operation Analysis & Material/Energy Balances

Instructions & Mathematical Formulation

This application automates the mass and enthalpy balance calculations for a Backward Feed Triple-Effect Evaporator system.

  • In backward feed operation, fresh feed solution enters Effect III ($F_1 = L_3$) and concentrated liquid is pumped sequentially toward Effect I ($L_3 \rightarrow L_2 \rightarrow L_1$), where product exits. Fresh steam $W_1$ enters Effect I.
  • Solute Material Balance: $$F_1 \cdot x_{F1} = L_1 \cdot x_{S3}$$
  • Overall Mass Balance: $$F_1 = L_1 + V_1 + V_2 + V_3$$
  • Enthalpy balances across all three effects are solved simultaneously using linear matrix systems.

Operating Conditions & Physical Parameters (SI Units)

1. Mass Flow & Pressures

2. Heat Capacities & Coefficients

3. Temperatures & Latent Heats

TRIPLE EFFECT BACKWARD FEED EVAPORATOR SKETCH

Steam & Vapor Flow
Backward Liquid Flow
1st EFFECT p1 (abs) 2nd EFFECT p2 (abs) 3rd EFFECT p3 (abs) Steam W1 = 0.000 kg/s Vapor V1 = 0.000 kg/s Vapor V2 = 0.000 kg/s Vapor V3 = 0.000 kg/s Feed F1 = 2.500 kg/s L3 = 2.500 kg/s L2 = 0.000 kg/s Product L1 = 0.500 kg/s

Na2SO4 Solution Boiling Temperature Estimator

🌡️ Na₂SO₄ Solutions App 🌡️

👨‍🎓 Author: JAQUELINE LARA VILLALOBOS 📅 Date: October 2026 👨‍🏫 Instructor: Dr. Ildebrando Pérez Reyes
Data Source: International Critical Tables of Numerical Data, Physics, Chemistry and Technology.

🔬 How it Works

This app uses experimental data to estimate properties of Sodium Sulfate ($\text{Na}_2\text{SO}_4$) solutions in water. The mathematical model applies Bilinear Interpolation over the pressure matrix $P(T, Wt\%)$.

Interpolation Model:
$$ f(x,y) \approx \frac{y_2 - y}{y_2 - y_1} f(x,y_1) + \frac{y - y_1}{y_2 - y_1} f(x,y_2) $$

By knowing any two variables (Temperature, Pressure, or Weight %), the system dynamically evaluates the adjacent data points from the experimental table to approximate the missing value.

📌 Instructions:
  1. Select Mode: Choose what variable you want to find (Temperature or Pressure).
  2. Input Data: Enter the known values within the experimental bounds (Wt% 0-30, Temp 0-100°C).
  3. Calculate: Click the button to interpolate the data instantly.

✅ Calculation Results

Concentration ($\text{Wt}\%$):
Vapor Pressure ($P_{\text{mm}}$):
Temperature (°C):
Temperature (°F):

Liquid Water Heat Capacity Calculator - K

Water Heat Capacity Calculator (1 atm)

Calculates the specific heat capacity ($c_P$) of liquid water at $101.325 \text{ kPa}$.

Author: Dana Ximena Gutierrez Martinez Date: October 20th 2026

Instructions: Enter the liquid water temperature in Kelvin ($K$) between $273.15 \text{ K}$ ($0^\circ\text{C}$) and $373.15 \text{ K}$ ($100^\circ\text{C}$). The heat capacity $c_P$ and its linear interpolation steps are computed dynamically.

cP result [kJ/kg K] 4.1799
cP result [cal/g °C] 0.9990
Linear Interpolation Breakdown
Tabulated Reference Points:
$T_1$: 290.00 K  |  $c_{P,1}$: 4.1840 kJ/kg·K (1.0000 cal/g·°C)
$T_2$: 300.00 K  |  $c_{P,2}$: 4.1790 kJ/kg·K (0.9988 cal/g·°C)
$$c_P = c_{P,1} + \frac{T - T_1}{T_2 - T_1} \left(c_{P,2} - c_{P,1}\right)$$
$$c_P \left[\text{kJ/kg}\cdot\text{K}\right] = 4.1840 + \frac{298.15 - 290.00}{300.00 - 290.00}(4.1790 - 4.1840) = 4.1799$$
$$c_P \left[\text{cal/g}^\circ\text{C}\right] = 1.0000 + \frac{298.15 - 290.00}{300.00 - 290.00}(0.9988 - 1.0000) = 0.9990$$

Source: C. J. Geankoplis, Transport Processes and Unit Operations.

Liquid Water Heat Capacity Calculator - °C

Liquid Water Heat Capacity Calculator

Author: Kenia García Rico | Date: October 20 2026

Instructions:

Enter the water temperature in degrees Celsius (\(^\circ\text{C}\)) within the range of \(0^\circ\text{C}\) to \(100^\circ\text{C}\) at a standard pressure of \(101.325\text{ kPa}\ (\text{1 atm})\). The application automatically interpolates the specific heat capacity (\(c_p\)) based on the tabulated data.

Range: 0 °C to 100 °C at 101.325 kPa (1 atm).

Interpolated Results:

\(c_p\) in $\text{cal}/(\text{g}\cdot ^\circ C)$: --

\(c_p\) in $\text{kJ}/(\text{kg}\cdot \text{K})$: --

Reference Data Table

Appendix A.2.5 Heat Capacity of Liquid Water at 101.325 kPa (1 atm)
\(T\) (°C) \(T\) (K) \(c_p\) [cal/(g·°C)] \(c_p\) [kJ/(kg·K)]
0273.151.00804.220
10283.151.00194.195
20293.150.99954.185
25298.150.99894.182
30303.150.99874.181
40313.150.99874.181
50323.150.99924.183
60333.151.00014.187
70343.151.00134.192
80353.151.00294.199
90363.151.00504.208
100373.151.00764.219

Methodology: Linear interpolation of exact tabulated values from Appendix A.2.5 "Capacidad calorífica del agua líquida a 101.325 kPa (1 atm)".

Source Citation: C. J. Geankoplis, Procesos de transporte y operaciones unitarias (3ª ed., 1998), Apéndice A.2.5, p. 945 (Basado en N. S. Osborne, H. F. Stimson y D. C. Ginnings, Bur. Standards J. Res., 23, 197, 1939).

Chemical Engineering Apps © 2026

Wednesday, October 21, 2026

NaCl Solution Boiling Temperature Estimator

NaCl Solution Boiling Temperature Estimator

Estimate the boiling temperature of an aqueous sodium chloride solution using absolute pressure and salt concentration.

Developed by: Daniela Cota Diaz
Date: October 2026

1. Instructions

  1. Enter the absolute pressure in mmHg.
  2. Enter the sodium chloride concentration in weight percent.
  3. Select Calculate to estimate the boiling temperature.
  4. The result will be displayed in degrees Celsius and Fahrenheit.

Valid ranges: 3.5–1074.5 mmHg and 0–25 wt.% NaCl. Results are estimated by linear interpolation of the included data.

2. Operating Conditions

Boiling Temperature — °C
Boiling Temperature — °F

3. Calculation Method

The program first interpolates the vapor pressure at the selected concentration for each tabulated temperature. It then interpolates between temperatures to estimate the boiling point at the specified pressure.

Linear interpolation:

\( y = y_1 + \dfrac{x-x_1}{x_2-x_1}(y_2-y_1) \)

Temperature conversion:

\( T(^{\circ}F) = \dfrac{9}{5}T(^{\circ}C) + 32 \)

The calculated temperature is an estimate based on the included tabulated values and linear interpolation between adjacent points.

4. Reference Data

The application uses a tabulated pressure dataset for aqueous NaCl solutions over a range of temperatures and concentrations.

View the data table

5. Reference

National Research Council. International Critical Tables of Numerical Data, Physics, Chemistry and Technology. Vapor-pressure data for aqueous sodium chloride solutions.

This educational estimator is intended for calculation practice. Verify data and assumptions before using results in engineering design.

Friday, September 11, 2026

Saturated Steam Properties Calculator - Temperature °C

Saturated Steam Properties Calculator

Created by: Nayomi Alvarez Contreras

Date: October 19, 2026

Reference: ASME Steam Tables: Compact Edition

Description

This application calculates saturated-water/steam properties at a specified temperature using the tabulated values in the ASME Steam Tables: Compact Edition. Results are shown in SI and British units.

Instructions

  1. Enter the temperature in degrees Celsius (°C).
  2. The accepted range is 0.01 °C to 373.946 °C.
  3. Press Calculate to display the four properties.
  4. Press Load Example to test the calculator at 100 °C.
  5. Press Clear to erase the input and results.

Equations

Latent heat of vaporization

\[h_{fg}=h_g-h_f\]

Enthalpy conversion

\[1\ \mathrm{kJ/kg}=0.4299226\ \mathrm{Btu/lb}\]

Absolute pressure conversion

\[1\ \mathrm{kPa}=0.1450377\ \mathrm{psia}\]

Input Data

Temperature, T (°C)

Results

Property SI Units British Units
Latent heat of vaporization, \(h_{fg}\)--
Absolute saturation pressure, \(P_{sat}\)--
Saturated-liquid enthalpy, \(h_f\)--
Saturated-vapor enthalpy, \(h_g\)--

Calculation method and reference

The program uses Table 4, “Properties of Saturated Water and Steam (Temperature),” from the ASME Steam Tables: Compact Edition. The pressure, saturated-liquid enthalpy (hL = hf), and saturated-vapor enthalpy (hV = hg) are taken from this table. For temperatures between listed rows, linear interpolation is used. Latent heat is calculated as hfg = hg − hf. British-unit results are converted from SI values.

Important: The ASME table lists values at 5 °C intervals over most of the range, so interpolated results may differ slightly from values calculated directly from the underlying IAPWS formulation. The critical-point entry is included. Pressure is absolute (kPa or psia), not gauge pressure. Reference: ASME, Steam Tables: Compact Edition, Table 4, SI units, printed pages 16–17.

Ideal gas mole calculator - SI

Ideal Gas Mole Calculator Created by: Nayomi Alvarez Contreras Date: November 15, 2026 Desc...