Followers

Showing posts with label Fluid mechanics. Show all posts
Showing posts with label Fluid mechanics. Show all posts

Friday, October 23, 2026

Fluid mechanics units converter

Fluid Mechanics Unit Converter

Convert engineering units instantly. Select a quantity, enter a value, and choose the input and output units. Conversion factors are based on standard engineering definitions commonly used in R. L. Mott's fluid mechanics textbooks.

Student: Marco Stuart Vázquez Holguín
University: Universidad Autónoma de Chihuahua — Facultad de Ciencias Químicas
Creation date: October 22, 2026

Bingham plastic fluid laminar flow calculator

Chemical Engineering

Laminar Flow Rate of a Bingham Plastic Fluid

An interactive calculator for volumetric flow rate, wall shear stress, and unit conversions.

1 Instructions

  1. Select the input unit system: SI or British Engineering Units.
  2. Enter the pipe inside diameter, pipe length, pressure drop, yield stress, and plastic viscosity.
  3. Click Calculate flow rate. The calculator converts the inputs to SI internally and displays results in both systems.
  4. Use the inside diameter, not the nominal pipe size. Pressure drop must be the pressure difference across the specified straight pipe length.

British inputs: diameter and length in ft; pressure drop and yield stress in lbf/ft2; plastic viscosity in lbf·s/ft2.

2 Input data

3 Equations and model

The Buckingham–Reiner equation calculates the volumetric flow rate for steady, fully developed laminar flow of a Bingham plastic fluid through a circular pipe.

Wall shear stress:

τw = ΔP · D / (4L)

Volumetric flow rate, when τw > τ0:

Q = [π D4 ΔP / (128 μp L)] × [1 − (4/3)(τ0/τw) + (1/3)(τ0/τw)4]

Average velocity and Reynolds-number estimate:

V = 4Q/(πD2),   Re = ρVD/μapp,w

For a screening estimate, apparent viscosity at the wall is approximated as μapp,w = μp + τ0/γ̇w, where γ̇w ≈ 8V/D. This is not a universal transition criterion for Bingham fluids.

Definitions: Q = volumetric flow rate; D = pipe inside diameter; L = pipe length; ΔP = pressure drop; μp = plastic viscosity; τ0 = yield stress; τw = wall shear stress.

4 Results

Enter the data and click “Calculate flow rate”.

5 Assumptions and limitations

  • Steady, incompressible, fully developed flow in a straight circular pipe.
  • Constant Bingham yield stress and plastic viscosity.
  • The pressure drop is attributed to the specified pipe length; elevation changes and minor losses are not included.
  • The calculator estimates the Reynolds number as a screening check. It does not prove laminar flow for every Bingham-fluid condition. Verify the applicable criterion taught in class before using the result for a real design.
  • If wall shear stress is less than or equal to the yield stress, the idealized model predicts no yielded flow.
Transport of Fluids • Unit 2 • Bingham Plastic Flow Rate Calculator

Power law fluid laminar flow calculator

Power Law Fluid Laminar Flow Calculator

Automated Real-Time Hydraulic & Rheological Solver for Non-Newtonian Fluids
Developer: Javier Noe Novo Castro
Date of Creation: October 22, 2026
Domain: Fluid Mechanics & Rheology
Governing Equations & Theoretical Formulations Ostwald-de Waele & Dodge-Metzner Models

1. Power Law Rheological Model

$$\tau = m \left( -\frac{dv}{dr} \right)^n$$
Shear stress $\tau$ as a function of consistency index $m$, velocity gradient, and flow behavior index $n$.

2. Volumetric Flow Rate & Mean Velocity

$$V = \left(\frac{D}{8}\right) \left[ \frac{D \Delta P g_c}{4 L m} \right]^{\frac{1}{n}} \left( \frac{4n}{3n+1} \right)$$ $$Q = \frac{\pi D^2}{4} V$$
Analytical integration over the circular cross section ($g_c = 32.174$ for British, $g_c = 1.0$ for SI).

3. Generalized Reynolds Number ($N_{Re}$)

$$N_{Re} = \frac{(4n)^n D^n V^{2-n} \rho}{g_c m (3n+1)^n 8^{n-1}}$$
Dodge & Metzner generalized Reynolds number for non-Newtonian laminar criterion ($N_{Re} < 2100$).

4. Friction Factor & Radial Velocity Profile

$$f_{FF-L} = \frac{16}{N_{Re}}$$ $$v(r) = V \left(\frac{3n+1}{n+1}\right) \left[ 1 - \left(\frac{r}{R}\right)^{\frac{n+1}{n}} \right]$$
Laminar Fanning friction factor $f_{FF-L}$ and radial velocity distribution $v(r)$ across pipe radius $R = D/2$.

5. Wall Shear Rate & Apparent Viscosity

$$\dot{\gamma}_w = \left(\frac{3n+1}{4n}\right) \left(\frac{8V}{D}\right)$$ $$\mu_{app,w} = m \cdot (\dot{\gamma}_w)^{n-1} = \frac{\tau_w}{\dot{\gamma}_w}$$
True shear rate at the wall $\dot{\gamma}_w$ and non-Newtonian apparent viscosity $\mu_{app,w}$ at wall stress $\tau_w = \frac{D \Delta P}{4L}$.
Input Parameters
m
m
Pa
kg/m3
dimensionless
n < 1: Pseudoplastic (Shear-thinning) | n = 1: Newtonian | n > 1: Dilatant (Shear-thickening)
Pa·sn
User Instructions & Application Guide
1
Select your preferred unit system (SI Units or British/Imperial Units) using the top toggle button.
2
Enter pipe geometry (D, L) and operating pressure drop (ΔP).
3
Provide Ostwald-de Waele rheological constants: flow behavior index n and consistency index m.
4
The app automatically updates Q, V, NRe, fFF-L, τw, γ̇w, μapp,w, and plots the radial velocity profile in real-time.
Hydrodynamic & Rheological Results
Volumetric Flow Rate (Q)
0.0000 m3/s
0.00 L/min
Mean Flow Velocity (V)
0.000 m/s
0.000 ft/s
Generalized Reynolds (NRe)
0.00
Laminar Regime
Fanning Friction Factor (fFF-L)
0.00000
Eq: fFF-L = 16 / NRe
Wall Shear Stress (τw)
0.00 Pa
0.00 lbf/ft2
Wall Shear Rate (γ̇w)
0.00 s-1
True wall shear rate
Apparent Viscosity at Wall (μapp,w)
0.00 Pa·s
0.00 cP
Centerline Max Velocity (vmax)
0.000 m/s
Ratio vmax/V
Laminar Radial Velocity Profile v(r) • Dynamic Real-Time Chart

Developed by Javier Noe Novo Castro © 2026 | Chemical Engineering & Fluid Mechanics Interactive Web Application

Hydraulic Grade Line (HGL), elevation & pressure calculator

Fluid Mechanics & Hydraulics • Dual-Unit Solver

Hydraulic Grade Line (HGL), Elevation & Pressure Calculator

Interactive engineering application to compute Hydraulic Grade Line (\(\text{HGL}\)), Elevation Head (\(z\)), or Static Pressure (\(P\)) with full conversion between SI and British units.

Application Metadata
Author: Fernando Lastra
Date Created: October 19, 2026
Math Engine: LaTeX (MathJax 3)
✓ Real-Time Automated Hydraulic Solver • SI (Metric) & British (Imperial) Units

How to Use This Application (Instructions)

Self-Explanatory Guide
Step 1: Choose Parameter Select which unknown variable you want to calculate: HGL, Elevation (\(z\)), or Pressure (\(P\)).
Step 2: Select Units Enter data in SI Units (\(\text{m}, \text{kPa}, \text{Pa}\)) or British Units (\(\text{ft}, \text{psi}, \text{psf}\)).
Step 3: Fluid Properties Keep default Standard Water (\(\gamma = 9810\text{ N/m}^3\)) or select another fluid / custom Specific Gravity (\(\text{SG}\)).
Step 4: Automated Output Results, step-by-step LaTeX equations, and the piezometric diagram update automatically in real time.

Governing Hydraulic Equations (LaTeX Formulation)

In fluid mechanics, the Hydraulic Grade Line (\(\text{HGL}\))—or piezometric head—represents the sum of elevation head (\(z\)) and static pressure head (\(h_p = \frac{P}{\gamma}\)):

1. Hydraulic Grade Line (\(\text{HGL}\))
$$\text{HGL} = z + \frac{P}{\gamma} = z + \frac{P}{\rho g}$$
2. Elevation / Height (\(z\))
$$z = \text{HGL} - \frac{P}{\gamma}$$
3. Static Pressure (\(P\))
$$P = \gamma \cdot \left(\text{HGL} - z\right)$$

Input Parameters

B. Unit System Preset: SI Units Active
Equivalent: 15.0000 m = 49.2126 ft
Equivalent: 198.1000 kPa = 28.7320 psi
SG = 1.000
Example Scenarios (1-Click Test):

Calculated Results

Solving for: Hydraulic Grade Line (HGL)
Computed Hydraulic Grade Line (HGL)
International System (SI)
35.1937 m
3519.37 cm • Head hp = 20.1937 m
British Units (Imperial)
115.4648 ft
1385.58 in • Head hp = 66.2522 ft
Hydraulic Parameter SI Units (Metric) British Units (Imperial)
Hydraulic Grade Line (\(\text{HGL}\)) 35.1937 m 115.4648 ft
Elevation / Height (\(z\)) 15.0000 m 49.2126 ft
Pressure Head (\(h_p = P/\gamma\)) 20.1937 m 66.2522 ft
Static Pressure (\(P\)) 198.100 kPa 28.7320 psi
Specific Weight (\(\gamma\)) 9810.0 N/m³ 62.4280 lb/ft³

Step-by-Step Mathematical Solution (LaTeX)

SI Derivation
$$\text{HGL}_{\text{SI}} = z + \frac{P}{\gamma} = 15.00 + \frac{198100}{9810} = 35.1937\text{ m}$$
British Derivation
$$\text{HGL}_{\text{BG}} = z + \frac{P}{\gamma} = 49.21 + \frac{4137.4}{62.43} = 115.4648\text{ ft}$$

Interactive Hydraulic Grade Line Schematic

Positive Gauge Pressure (\(P > 0\))
Reference Datum Plane (z = 0 m | 0 ft) HGL = 35.19 m (115.46 ft) z = 15.00 m (49.21 ft) P/γ = 20.19 m (66.25 ft) HGL = 35.19 m (115.5 ft)
Developed by Fernando Lastra • Created on October 19, 2026
Blogger Standalone HTML5 Application • Dual SI & British Solver

Ideal gas mole calculator - SI

Ideal Gas Mole Calculator Created by: Nayomi Alvarez Contreras Date: November 15, 2026 Desc...